TSA-001 sealed plunger actuator Limit Switch
■ Stainless steel idler wheel, punch and spring;
■ Selective M18x1.5 cable gland.
Ratings
Rated voltage
|
Noninductive Load (A)
|
Inductive Load (A)
|
Resistance Load
|
Lamp Load
|
Inductive Load (A)
|
Motor Load
|
NC
|
NO
|
NC
|
NO
|
NC
|
NO
|
NC
|
NO
|
125VAC
|
5
|
5
|
1.5
|
0.7
|
3
|
3
|
2
|
1
|
250VAC
|
5
|
5
|
1
|
0.5
|
3
|
3
|
1.5
|
0.8
|
8VDC
|
5
|
5
|
3
|
3
|
5
|
4
|
3
|
3
|
14VDC
|
5
|
5
|
3
|
3
|
4
|
4
|
3
|
3
|
30VDC
|
5
|
5
|
3
|
3
|
4
|
4
|
3
|
3
|
125VDC
|
0.4
|
0.4
|
|
|
|
|
|
|
250VDC
|
0.2
|
0.2
|
|
|
|
|
|
|
Inrush Current
|
N.C: below 24A, N.O: below 12A
|
NOTE:
1. Inductive load has a power factor of 0.4 min.(AC) and a time constant of 7 msec.max.(DC).
2. Lamp load has an inrush current of 10 times the steady-state current,while motor load has an inrush current of 6 times the steady-state current.
3. Product with spring, its usable range of operating part is within one third of the whole spring length from the front end of spring.
Characteristics
Operation speed
|
0.5mm-50cm/sec
|
Operating frequency
|
Electical: 30 operations/minute
|
Contact resistance
|
25mΩ max. (initial value)
|
Insulation resistance
|
100MΩ min. (below 500VDC)
|
Dielectric Strength
|
1000VAC, 50/60 Hz for 1 minute between terminals of the same polarity
|
1500VAC, 50/60 Hz for 1 minute between current-carrying and non-current-carrying metal parts
|
1500VAC, 50/60 Hz for 1 minute between each terminal and ground
|
Vibration
|
10-55Hz,1.5mm double amplitude
|
Shock
|
Mechanical durable: 1, 000m/Sec2 (about 100G'S)
Malfunction: 300m/Sec2 (about 30G'S)
|
Ambient Temperature
|
-10~+65℃ (With no icing)
|
Humidity
|
<95% RH
|
Weight
|
About 195 to 246g
|
Electrical Life
|
Above 500000
|
Degree of protection
|
IP65
|