Product Description

T4N-4131 Safety Limit Switch

■ Forced open action device(NC contacts only), it can disconnect the contact when the contact has fusing and other failures.

■ Standardized gold-clad contacts provide high contact reliability, Can be used with both standard loads and microloads.

■ Strengthened top seal structure improves the sealing performance.

■ Built-in contact holder has fast-action type: 1NC/1NO; Slow-action: 1NC /1NO and 2NC.

 

Characteristics

Protection level*1

IP66

Life*2

Electrical

More than 300,000 times (AC250V 10A, resistive load)

Electrical

More than 500,000 times (AC250V 3A, resistive load) *3

Operating speed

1 500mm/s(T4N-4120)

Operating frequency

Max. 30 times/min

Contact resistance

25 mΩ or less

Minimum working load *4

1mA resistive load below DC5V (N standard reference value)

Rated insulation voltage (Ui)

300V

Electric shock proof protection grade

Class II (double insulated)

Pollution degree (environmental conditions)

Pollution degree 3 (EN60947-5-1)

Withstand voltage
(EN60947-5-1)

Between homopolar terminals: 2.5kV

Between heteropolar terminals: 2.5kV

Between terminals and uncharged metal parts: 6kV

insulation resistance

Above 100MΩ

Contact gap

Minimum 2×0.5mm quick-action type,
Minimum 2×2mm slow-action type

Vibration

Malfunction

10 55Hz 0.75mm single amplitude

Impact

Duration

1,000m/s2

Malfunction

300m/s2

Ambient temperature

-20 +70℃ (No ice or dew)

Ambient humidity

Less than 95% RH

Weight

About 73g (T4N-4120)

About 82g (T4N-4120 with gland)

 

Note1:The above values are initial values.

Note2:Once the contact is connected to a standard load, it can not be used to connect a smaller load. If so, the contact may result in rough surface, thus losing contact reliability.

①The protection level is gotten based on test method of (EN60947-5-1). Please make sure its sealing under actual environmental conditions before use. The switch box has dust and oil resistance structure, but it should be used in places without dust, oil and chemicals.

Otherwise it may lead to premature wear, damage or malfunction.

②The durability is for ambient temperature of 5℃ ~ 35℃ and humidity of 40% to 70% RH.

③For additional details, please contact us.

④When the ambient temperature is above 35℃ , more than 2 circuits 3A 250VAC loads are prohibited.

⑤The values will vary with different switching frequency, environmental conditions, reliability level and other factors. Please confirm on the actual load in advance.

The mechanical life of deadman lever type is more than 10,000,000 times.